Amplifier
> 제조상품 > Amplifier>FUNCTION - Fully adjustable calibrated gain from 1 to 11000
- Accepts all strain gage inputs (foil or piezoresistive), potentiometer, DCDT's, etc.
- Bridge excitation from 1 to 10Vdc(5 steps)
- Input impedance above 1GΩ.
- Four-frequency low-pass active filter (10Hz to 10kHz)
- Automatic bridge balance (± 4000με)
- Double shunt calibration (120Ω, 350Ω, 2000με, 200με)
- Outputs voltage display (7-segment 4-digits LED)
- Size : 218 (H) × 43 (W) × 258 (D) (mm)
- Weight : Approx. 1.2kg>SPECIFICATION Excitation 5 steps : 1V, 2V, 5V, 7.5V, 10V Current : 170mA, max. Remote sensing circuit : error -0.0005%/Ω at lead resistance (350Ω load) Noise and ripple : 0.05% p-p, max (dc 10kHz) Stability : ± 0.01%/℃ Input Strain gauge
: quarter, half or full bridge (50 to 1000Ω). Built-in 120Ω and 350Ω dummy resisterTransducer
: Piezoresistive strain gauge types,potentiometer,DCDT transducers displacement.Amplifier 1st Gain : × 1, × 10, × 100, × 400, × 1000 5steps 2nd Gain : × 1 to × 11 continuously variable Vernier multiplier : 10-turn counting knob with direct readout Fine Adjust Frequence response : 100kHz (-3dB), max Input resistance : 1GΩ, differential or common mode Input capacitance : 4pF, differential or common mode Input voltage range : ±10V, differential mode 12V-(G/2×Vd), common mode (Vd=actual differential input voltage) Bias current : ± 30nA, typical, each input Common-mode rejection (G=100) : 100dB, min, dc to 60Hz with 1kΩ source imbalance Stability (G <1000) : 5ppm/℃, max Noise (G=100) : 0.01 to 10Hz, 0.3μVp-p R.T.I Filter Characteristic : low-pass active 2-pole Butterworth standard Frequencies (-3dB) : 10Hz, 100Hz, 1kHz, 10kHz, wide-band Amplifier output
(BNC connector)Output 1 : ± 10V @100mA max Output 2 ; ± 10V @10mA max Monitor voltage display Display character : 7-segment 4-digits LED Display range : 0.000V ~ ± 10.00V Monitor test terminal EXC+, - / SIG+,- / OUT+,- GAIN 1 ~ 11000 magnifications, Max Frequency response 100kHz (-3dB), Max Bridge balance Auto ranging : ± 4000με (2mV/V) Auto balance time : 1 second, typical Manual balance range : ± 1V Storage : non-volatile data memory (EEPROM) Low pass filter 4 steps 10Hz, 100Hz, 1kHz, 10kHz (-3dB) Linearity ±0.01% Stability ±0.01%℃ Shunt calibration Bridge resistance 120Ω : 200με and 2000με calibrations Bridge resistance 350Ω : 200με and 2000με calibrations Input impedance more than 1GΩ Power AC 110V or 220V (switch selected), 50/60Hz, 7.5watts 3-Wire line code (2-wire : Power / 1-wire : Ground) >DIMENSION -
제품 사양은 변경 될 수 있습니다.
제품마다 납기는 차이가 있을 수 있습니다.